廈門服務器租用>業界新聞>中型數據中心UPS解(jie)決方案

中型數據中心UPS解決方案

發布時間:2013/3/9 15:54:10    來源: 縱橫數據

中型數(shu)據中心(xin)的(de)基礎設(she)(she)施系統主要(yao)分(fen)電(dian)源、環境控制和機房監(jian)控管理系統。由(you)于(yu)中型數(shu)據中心(xin)承載企業(ye)、機構的(de)核心(xin)業(ye)務,重要(yao)性較高。因而中型數(shu)據中心(xin)一般根(gen)據TIA942標準的(de)Tier4和Tier3標準建設(she)(she),可靠(kao)性要(yao)求99.999%以(yi)上,以(yi)保(bao)證(zheng)大部分(fen)異常故障和正(zheng)常維護情況(kuang)下(xia),數(shu)據中心(xin)正(zheng)常工(gong)作,核心(xin)業(ye)務不受(shou)影(ying)響。

  1、電(dian)(dian)(dian)(dian)源(yuan)系統(tong),通常選用(yong)多路市電(dian)(dian)(dian)(dian)源(yuan)互為備(bei)份,并且機(ji)房設有(you)專用(yong)柴油發電(dian)(dian)(dian)(dian)機(ji)系統(tong)作為備(bei)用(yong)電(dian)(dian)(dian)(dian)源(yuan)系統(tong),市電(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)源(yuan)間(jian)、市電(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)源(yuan)和柴油發電(dian)(dian)(dian)(dian)機(ji)間(jian)通過(guo)ATS(自(zi)動切(qie)換(huan)開關)進(jin)行切(qie)換(huan),為數據中心內UPS(不(bu)間(jian)斷供(gong)電(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)源(yuan))、機(ji)房空(kong)調(diao)、照明等設備(bei)供(gong)電(dian)(dian)(dian)(dian)。

  由于中(zhong)型數(shu)(shu)據中(zhong)心(xin)業務(wu)(wu)重要(yao)性,通常(chang)采用(yong)雙母(mu)(mu)(mu)線(xian)或冗余(yu)并(bing)機(ji)的(de)供(gong)(gong)(gong)(gong)電(dian)(dian)(dian)方(fang)案供(gong)(gong)(gong)(gong)電(dian)(dian)(dian),滿(man)足中(zhong)型數(shu)(shu)據中(zhong)心(xin)服務(wu)(wu)器等IT設(she)備高可靠性用(yong)電(dian)(dian)(dian)要(yao)求(qiu)。雙母(mu)(mu)(mu)線(xian)供(gong)(gong)(gong)(gong)電(dian)(dian)(dian)系統(tong)(tong),有兩套(tao)獨立UPS供(gong)(gong)(gong)(gong)電(dian)(dian)(dian)系統(tong)(tong)(包(bao)含(han)UPS配(pei)電(dian)(dian)(dian)系統(tong)(tong)),在(zai)任一套(tao)供(gong)(gong)(gong)(gong)電(dian)(dian)(dian)母(mu)(mu)(mu)線(xian)(供(gong)(gong)(gong)(gong)電(dian)(dian)(dian)系統(tong)(tong))需要(yao)維護或故(gu)障等無(wu)法正(zheng)常(chang)供(gong)(gong)(gong)(gong)電(dian)(dian)(dian)的(de)情況下,另一套(tao)供(gong)(gong)(gong)(gong)電(dian)(dian)(dian)母(mu)(mu)(mu)線(xian)仍能承擔所有負載,保證(zheng)機(ji)房業務(wu)(wu)供(gong)(gong)(gong)(gong)電(dian)(dian)(dian),確保數(shu)(shu)據中(zhong)心(xin)業務(wu)(wu)不受影響。冗余(yu)并(bing)機(ji)供(gong)(gong)(gong)(gong)電(dian)(dian)(dian)系統(tong)(tong),采用(yong)UPS冗余(yu)并(bing)機(ji)的(de)方(fang)式,提(ti)高供(gong)(gong)(gong)(gong)電(dian)(dian)(dian)系統(tong)(tong)的(de)可靠性,保證(zheng)數(shu)(shu)據中(zhong)心(xin)供(gong)(gong)(gong)(gong)電(dian)(dian)(dian)。

  在(zai)UPS輸出到(dao)服務器(qi)等(deng)IT設(she)(she)備(bei)輸入間,選(xuan)(xuan)用(yong)SPM(服務器(qi)電(dian)(dian)(dian)(dian)源(yuan)(yuan)管(guan)理(li)器(qi))進行(xing)電(dian)(dian)(dian)(dian)源(yuan)(yuan)分(fen)配(pei)和供(gong)(gong)電(dian)(dian)(dian)(dian)管(guan)理(li),實現對每(mei)臺機柜(ju)用(yong)電(dian)(dian)(dian)(dian)監控管(guan)理(li),提(ti)高供(gong)(gong)電(dian)(dian)(dian)(dian)系(xi)(xi)統的(de)可(ke)靠(kao)性和易(yi)管(guan)理(li)性。對于雙路電(dian)(dian)(dian)(dian)源(yuan)(yuan)的(de)服務器(qi)等(deng)IT設(she)(she)備(bei),可(ke)以通過(guo)SPM直(zhi)接從雙母(mu)線供(gong)(gong)電(dian)(dian)(dian)(dian)系(xi)(xi)統的(de)兩(liang)套(tao)(tao)母(mu)線引人電(dian)(dian)(dian)(dian)源(yuan)(yuan),即可(ke)保證其(qi)用(yong)電(dian)(dian)(dian)(dian)高可(ke)靠(kao)性。對于單路電(dian)(dian)(dian)(dian)源(yuan)(yuan)的(de)服務器(qi)等(deng)IT設(she)(she)備(bei),通常選(xuan)(xuan)用(yong)STS(靜態切換(huan)開關)為其(qi)選(xuan)(xuan)擇切換(huan)一套(tao)(tao)供(gong)(gong)電(dian)(dian)(dian)(dian)母(mu)線供(gong)(gong)電(dian)(dian)(dian)(dian)。在(zai)供(gong)(gong)電(dian)(dian)(dian)(dian)母(mu)線無法正常供(gong)(gong)電(dian)(dian)(dian)(dian)時,STS將自動快(kuai)速切換(huan)到(dao)另(ling)一套(tao)(tao)供(gong)(gong)電(dian)(dian)(dian)(dian)正常的(de)母(mu)線供(gong)(gong)電(dian)(dian)(dian)(dian),確保服務器(qi)等(deng)IT設(she)(she)備(bei)的(de)可(ke)靠(kao)用(yong)電(dian)(dian)(dian)(dian)。

圖示冗(rong)余并機供電(dian)(dian)系統可(ke)確(que)保供電(dian)(dian)可(ke)靠性高(gao)達(da)99.999%以上(shang) 圖示雙母線供電(dian)(dian)系統可(ke)確(que)保供電(dian)(dian)可(ke)靠性高(gao)達(da)99.99999%以上(shang)

  2、環境(jing)控制系統,通常(chang)選用機房精密空(kong)調對(dui)數據中心(xin)的(de)環境(jing)調節,確保(bao)服(fu)務器等(deng)IT設(she)(she)備(bei)(bei)的(de)運行(xing)環境(jing)。對(dui)于(yu)發熱量(liang)大的(de)服(fu)務器等(deng)IT設(she)(she)備(bei)(bei),通常(chang)選用高(gao)(gao)通孔(kong)率(lv)(一般大于(yu)70%)網孔(kong)門的(de)機柜(ju),提高(gao)(gao)機柜(ju)進出風量(liang);將機柜(ju)面對(dui)面、背對(dui)背布置(zhi),在機房內形成(cheng)冷熱隔離(li)的(de)風道,提高(gao)(gao)制冷效(xiao)率(lv);空(kong)調采用下(xia)送風方式,確保(bao)機房送風均(jun)勻(yun),提高(gao)(gao)制冷效(xiao)率(lv)。

  在(zai)(zai)某些功率密度特別高(gao)(gao)場合(發熱(re)量超(chao)過5kw/機柜),往往容易(yi)產生(sheng)局部(bu)熱(re)點(dian),形成故(gu)障隱患(huan)。為(wei)消除局部(bu)熱(re)點(dian),需要采用相應的高(gao)(gao)熱(re)密度解決方案,如(ru)開放式方案即為(wei)在(zai)(zai)局部(bu)熱(re)點(dian)發生(sheng)處加裝制(zhi)(zhi)冷(leng)終(zhong)端(duan)XD,加強(qiang)局部(bu)制(zhi)(zhi)冷(leng)能力,以消除局部(bu)熱(re)點(dian);封閉式方案即為(wei)高(gao)(gao)功率密度設備放置在(zai)(zai)封閉機柜內,通(tong)過機柜內制(zhi)(zhi)冷(leng)循環,高(gao)(gao)效率制(zhi)(zhi)冷(leng)散熱(re)。

  3、機(ji)(ji)房(fang)監(jian)控(kong)管理(li)系統,中(zhong)型數據(ju)中(zhong)心(xin)需要(yao)對(dui)電源(yuan)、空調(diao)等設備運行狀態進行管理(li),同時還(huan)需要(yao)對(dui)機(ji)(ji)房(fang)內環境(jing),如溫濕度、漏水、煙感等參(can)(can)量進行監(jian)控(kong),確(que)保數據(ju)中(zhong)心(xin)工作在一個正常的(de)范圍之內。并(bing)對(dui)數據(ju)中(zhong)心(xin)設備運行參(can)(can)數和(he)環境(jing)量實時監(jian)控(kong)和(he)管理(li),同時遠程監(jian)控(kong)和(he)管理(li),實現機(ji)(ji)房(fang)無人值守。

文章來源于縱橫數據(